VmWare/HP Raid
From r00tedvw.com wiki
(Difference between revisions)
(→Reference Material) |
|||
Line 50: | Line 50: | ||
[http://h20565.www2.hp.com/portal/site/hpsc/template.PAGE/public/psi/mostViewedDisplay?javax.portlet.begCacheTok=com.vignette.cachetoken&javax.portlet.endCacheTok=com.vignette.cachetoken&javax.portlet.prp_efb5c0793523e51970c8fa22b053ce01=wsrp-navigationalState%3DdocId%253Dmmr_kc-0110258-5%257CdocLocale%253Den_US&javax.portlet.tpst=efb5c0793523e51970c8fa22b053ce01&sp4ts.oid=316599&ac.admitted=1393292964741.876444892.492883150 public announcement hpacucli is replaced by hpssacli]<br> | [http://h20565.www2.hp.com/portal/site/hpsc/template.PAGE/public/psi/mostViewedDisplay?javax.portlet.begCacheTok=com.vignette.cachetoken&javax.portlet.endCacheTok=com.vignette.cachetoken&javax.portlet.prp_efb5c0793523e51970c8fa22b053ce01=wsrp-navigationalState%3DdocId%253Dmmr_kc-0110258-5%257CdocLocale%253Den_US&javax.portlet.tpst=efb5c0793523e51970c8fa22b053ce01&sp4ts.oid=316599&ac.admitted=1393292964741.876444892.492883150 public announcement hpacucli is replaced by hpssacli]<br> | ||
[https://h20565.www2.hp.com/portal/site/hpsc/template.BINARYPORTLET/public/kb/docDisplay/resource.process/?spf_p.tpst=kbDocDisplay_ws_BI&spf_p.rid_kbDocDisplay=docDisplayResURL&javax.portlet.begCacheTok=com.vignette.cachetoken&spf_p.rst_kbDocDisplay=wsrp-resourceState%3DdocId%253Demr_na-c03934591-1%257CdocLocale%253Den_US&javax.portlet.endCacheTok=com.vignette.cachetoken HP PDF]<br> | [https://h20565.www2.hp.com/portal/site/hpsc/template.BINARYPORTLET/public/kb/docDisplay/resource.process/?spf_p.tpst=kbDocDisplay_ws_BI&spf_p.rid_kbDocDisplay=docDisplayResURL&javax.portlet.begCacheTok=com.vignette.cachetoken&spf_p.rst_kbDocDisplay=wsrp-resourceState%3DdocId%253Demr_na-c03934591-1%257CdocLocale%253Den_US&javax.portlet.endCacheTok=com.vignette.cachetoken HP PDF]<br> | ||
+ | ==Update P400/i Firmware== | ||
+ | Visit: [http://h20565.www2.hp.com/portal/site/hpsc/template.PAGE/public/psi/swdDetails/?sp4ts.oid=1157693&spf_p.tpst=swdMain&spf_p.prp_swdMain=wsrp-navigationalState%3Didx%253D%257CswItem%253DMTX_bc1046a3541a46389b7fa2d755%257CswEnvOID%253D54%257CitemLocale%253D%257CswLang%253D%257Cmode%253D%257Caction%253DdriverDocument&javax.portlet.begCacheTok=com.vignette.cachetoken&javax.portlet.endCacheTok=com.vignette.cachetoken hp download site] | ||
+ | Download: [http://ftp.hp.com/pub/softlib2/software1/sc-linux-fw-array/p1174979133/v78323/CP017698.scexe CP017698.scexe] | ||
+ | <br> | ||
+ | copy to /tmp/downloads/ on VmWare esxi 5.1 box. I generally use SCP to copy from a linux system.<br> | ||
+ | launch | ||
+ | /tmp/downloads/ # ./CP017698.scexe | ||
+ | HP Enclosure ROM Flash. | ||
+ | Flash Engine Version: 2.06.10 | ||
+ | Copyright (c) 2006-2009 Hewlett-Packard Development Company L.P. | ||
+ | |||
+ | Device [P400]: FW Ver [ Current:4.06 | Apply:7.24 ?]Flash this device? [NO, yes, quit] yes | ||
+ | Preparing to flash devices on the array controller... | ||
+ | Requesting flash - this could take up to 15 minutes... | ||
+ | Flash complete. | ||
+ | The array flash operation succeeded. | ||
+ | Device [P400]: FW Ver [ Current:4.06 | Apply:7.24 ?]Flash this device? [NO, yes, quit] yes | ||
+ | Preparing to flash devices on the array controller... | ||
+ | Requesting flash - this could take up to 15 minutes... | ||
+ | Flash complete. | ||
+ | The array flash operation succeeded. | ||
+ | /tmp/downloads # | ||
+ | Reboot | ||
+ | /tmp/downloads # reboot | ||
+ | Check to make sure it's updated | ||
+ | /tmp/downloads # esxcli hpssacli cmd -q "controller all show config detail" | grep "Firmware Version" | ||
+ | Firmware Version: 7.24 |
Revision as of 19:36, 18 March 2014
Contents[hide] |
Download
google search =dl380 proliant smart array controller driver for vmware esxi 5.0
Proliant Smart Array Controller Driver - VIB file
HP ESXi Utilities Offline Bundle
Install
vib installation
esxcli software vib install -v [vib full path]
zip installation
esxcli software vib install -d [zip full path]
Installation Confirmation
Reboot required first.
Verify installation completed
~ # esxcli software vib list | grep Hewlett hpssacli 1.60.17.0-5.0.0.377826 Hewlett-Packard PartnerSupported 2011-05-07 scsi-hpsa 5.0.0.58-1OEM.500.0.0.472560 Hewlett-Packard VMwareCertified 2011-05-07
Test with query
/opt/hp/hpssacli/bin # esxcli hpssacli cmd -q "controller all show status " Smart Array P400i in Slot 0 (Embedded) Controller Status: OK Cache Status: OK /opt/hp/hpssacli/bin # esxcli hpssacli cmd -q "controller all show config " Smart Array P400i in Slot 0 (Embedded) (sn: PH79MV8506 ) array A (SATA, Unused Space: 0 MB) logicaldrive 1 (465.7 GB, RAID 1, OK) physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SATA, 500 GB, OK) physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SATA, 500 GB, OK) array B (SATA, Unused Space: 0 MB) logicaldrive 2 (1.4 TB, RAID 5, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SATA, 500 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SATA, 500 GB, OK) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SATA, 500 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SATA, 500 GB, OK)
Reference Material
install/config (obsolete)
command cheat sheet (obsolete)
public announcement hpacucli is replaced by hpssacli
HP PDF
Update P400/i Firmware
Visit: hp download site
Download: CP017698.scexe
copy to /tmp/downloads/ on VmWare esxi 5.1 box. I generally use SCP to copy from a linux system.
launch
/tmp/downloads/ # ./CP017698.scexe HP Enclosure ROM Flash. Flash Engine Version: 2.06.10 Copyright (c) 2006-2009 Hewlett-Packard Development Company L.P. Device [P400]: FW Ver [ Current:4.06 | Apply:7.24 ?]Flash this device? [NO, yes, quit] yes Preparing to flash devices on the array controller... Requesting flash - this could take up to 15 minutes... Flash complete. The array flash operation succeeded. Device [P400]: FW Ver [ Current:4.06 | Apply:7.24 ?]Flash this device? [NO, yes, quit] yes Preparing to flash devices on the array controller... Requesting flash - this could take up to 15 minutes... Flash complete. The array flash operation succeeded. /tmp/downloads #
Reboot
/tmp/downloads # reboot
Check to make sure it's updated
/tmp/downloads # esxcli hpssacli cmd -q "controller all show config detail" | grep "Firmware Version" Firmware Version: 7.24