VmWare/HP Raid
From r00tedvw.com wiki
(Difference between revisions)
| Line 8: | Line 8: | ||
zip installation<br> | zip installation<br> | ||
esxcli software vib install -d [zip full path] | esxcli software vib install -d [zip full path] | ||
| + | ==Installation Confirmation== | ||
| + | Reboot required first.<br> | ||
| + | Verify installation completed<br> | ||
| + | ~ # esxcli software vib list | grep Hewlett | ||
| + | hpssacli 1.60.17.0-5.0.0.377826 Hewlett-Packard PartnerSupported 2011-05-07 | ||
| + | scsi-hpsa 5.0.0.58-1OEM.500.0.0.472560 Hewlett-Packard VMwareCertified 2011-05-07 | ||
| + | Test with query | ||
| + | /opt/hp/hpssacli/bin # esxcli hpssacli cmd -q "controller all show status " | ||
| + | |||
| + | Smart Array P400i in Slot 0 (Embedded) | ||
| + | Controller Status: OK | ||
| + | Cache Status: OK | ||
| + | |||
| + | |||
| + | |||
| + | /opt/hp/hpssacli/bin # esxcli hpssacli cmd -q "controller all show config " | ||
| + | |||
| + | Smart Array P400i in Slot 0 (Embedded) (sn: PH79MV8506 ) | ||
| + | |||
| + | array A (SATA, Unused Space: 0 MB) | ||
| + | |||
| + | |||
| + | logicaldrive 1 (465.7 GB, RAID 1, OK) | ||
| + | |||
| + | physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SATA, 500 GB, OK) | ||
| + | physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SATA, 500 GB, OK) | ||
| + | |||
| + | array B (SATA, Unused Space: 0 MB) | ||
| + | |||
| + | |||
| + | logicaldrive 2 (1.4 TB, RAID 5, OK) | ||
| + | |||
| + | physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SATA, 500 GB, OK) | ||
| + | physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SATA, 500 GB, OK) | ||
| + | physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SATA, 500 GB, OK) | ||
| + | physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SATA, 500 GB, OK) | ||
Revision as of 22:10, 24 February 2014
Download
google search =dl380 proliant smart array controller driver for vmware esxi 5.0
Proliant Smart Array Controller Driver - VIB file
HP ESXi Utilities Offline Bundle
Install
vib installation
esxcli software vib install -v [vib full path]
zip installation
esxcli software vib install -d [zip full path]
Installation Confirmation
Reboot required first.
Verify installation completed
~ # esxcli software vib list | grep Hewlett hpssacli 1.60.17.0-5.0.0.377826 Hewlett-Packard PartnerSupported 2011-05-07 scsi-hpsa 5.0.0.58-1OEM.500.0.0.472560 Hewlett-Packard VMwareCertified 2011-05-07
Test with query
/opt/hp/hpssacli/bin # esxcli hpssacli cmd -q "controller all show status "
Smart Array P400i in Slot 0 (Embedded)
Controller Status: OK
Cache Status: OK
/opt/hp/hpssacli/bin # esxcli hpssacli cmd -q "controller all show config "
Smart Array P400i in Slot 0 (Embedded) (sn: PH79MV8506 )
array A (SATA, Unused Space: 0 MB)
logicaldrive 1 (465.7 GB, RAID 1, OK)
physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SATA, 500 GB, OK)
physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SATA, 500 GB, OK)
array B (SATA, Unused Space: 0 MB)
logicaldrive 2 (1.4 TB, RAID 5, OK)
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SATA, 500 GB, OK)
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SATA, 500 GB, OK)
physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SATA, 500 GB, OK)
physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SATA, 500 GB, OK)