VmWare/HP Raid
From r00tedvw.com wiki
Contents[hide] |
Download
google search =dl380 proliant smart array controller driver for vmware esxi 5.0
Proliant Smart Array Controller Driver - VIB file
HP ESXi Utilities Offline Bundle
Install
vib installation
esxcli software vib install -v [vib full path]
zip installation
esxcli software vib install -d [zip full path]
Installation Confirmation
Reboot required first.
Verify installation completed
~ # esxcli software vib list | grep Hewlett hpssacli 1.60.17.0-5.0.0.377826 Hewlett-Packard PartnerSupported 2011-05-07 scsi-hpsa 5.0.0.58-1OEM.500.0.0.472560 Hewlett-Packard VMwareCertified 2011-05-07
Test with query
/opt/hp/hpssacli/bin # esxcli hpssacli cmd -q "controller all show status " Smart Array P400i in Slot 0 (Embedded) Controller Status: OK Cache Status: OK /opt/hp/hpssacli/bin # esxcli hpssacli cmd -q "controller all show config " Smart Array P400i in Slot 0 (Embedded) (sn: PH79MV8506 ) array A (SATA, Unused Space: 0 MB) logicaldrive 1 (465.7 GB, RAID 1, OK) physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SATA, 500 GB, OK) physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SATA, 500 GB, OK) array B (SATA, Unused Space: 0 MB) logicaldrive 2 (1.4 TB, RAID 5, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SATA, 500 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SATA, 500 GB, OK) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SATA, 500 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SATA, 500 GB, OK)
Reference Material
install/config (obsolete)
command cheat sheet (obsolete)
public announcement hpacucli is replaced by hpssacli
HP PDF