VmWare/HP Raid

From r00tedvw.com wiki
Revision as of 00:49, 19 March 2014 by R00t (Talk | contribs)

Jump to: navigation, search

Contents

Download

google search =dl380 proliant smart array controller driver for vmware esxi 5.0
Proliant Smart Array Controller Driver - VIB file
HP ESXi Utilities Offline Bundle

Install

vib installation

esxcli software vib install -v [vib full path]
i.e.
esxcli software vib install -v /vmfs/volumes/RAID1_Disks3_4/ISOs/vib/hp_raid/hp-HPUtil-esxi5.0-bundle-1.6
-19/hpssacli-1.60.17.0-5.0.0.vib

zip installation

esxcli software vib install -d [zip full path]

Installation Confirmation

Reboot required first.
Verify installation completed

~ # esxcli software vib list | grep Hewlett
hpssacli                       1.60.17.0-5.0.0.377826              Hewlett-Packard  PartnerSupported  2011-05-07  
scsi-hpsa                      5.0.0.58-1OEM.500.0.0.472560        Hewlett-Packard  VMwareCertified   2011-05-07

Test with query

/opt/hp/hpssacli/bin # esxcli hpssacli cmd -q "controller all show status "

Smart Array P400i in Slot 0 (Embedded)
   Controller Status: OK
   Cache Status: OK



/opt/hp/hpssacli/bin # esxcli hpssacli cmd -q "controller all show config "

Smart Array P400i in Slot 0 (Embedded)    (sn: PH79MV8506     )

   array A (SATA, Unused Space: 0  MB)


      logicaldrive 1 (465.7 GB, RAID 1, OK)

      physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SATA, 500 GB, OK)
      physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SATA, 500 GB, OK)

   array B (SATA, Unused Space: 0  MB)


      logicaldrive 2 (1.4 TB, RAID 5, OK)

      physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SATA, 500 GB, OK)
      physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SATA, 500 GB, OK)
      physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SATA, 500 GB, OK)
      physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SATA, 500 GB, OK)

Reference Material

install/config (obsolete)
command cheat sheet (obsolete)
public announcement hpacucli is replaced by hpssacli
HP PDF

Update P400/i Firmware

Visit: hp download site Download: CP017698.scexe
copy to /tmp/downloads/ on VmWare esxi 5.1 box. I generally use SCP to copy from a linux system.
launch

/tmp/downloads/ # ./CP017698.scexe
HP Enclosure ROM  Flash.
Flash Engine Version: 2.06.10
Copyright (c) 2006-2009 Hewlett-Packard Development Company L.P.

Device [P400]:  FW Ver [ Current:4.06 | Apply:7.24 ?]Flash this device? [NO, yes, quit] yes
Preparing to flash devices on the array controller...
Requesting flash - this could take up to 15 minutes...
Flash complete.
The array flash operation succeeded.
Device [P400]:  FW Ver [ Current:4.06 | Apply:7.24 ?]Flash this device? [NO, yes, quit] yes
Preparing to flash devices on the array controller...
Requesting flash - this could take up to 15 minutes...
Flash complete.
The array flash operation succeeded.
/tmp/downloads #

Reboot

/tmp/downloads # reboot

Check to make sure it's updated

/tmp/downloads # esxcli hpssacli cmd -q "controller all show config detail" | grep "Firmware Version"
  Firmware Version: 7.24
Personal tools
Namespaces

Variants
Actions
Navigation
Mediawiki
Confluence
DevOps Tools
Ubuntu
Ubuntu 22
Mac OSX
Oracle Linux
AWS
Windows
OpenVPN
Grafana
InfluxDB2
TrueNas
OwnCloud
Pivotal
osTicket
OTRS
phpBB
WordPress
VmWare ESXI 5.1
Crypto currencies
HTML
CSS
Python
Java Script
PHP
Raspberry Pi
Canvas LMS
Kaltura Media Server
Plex Media Server
MetaSploit
Zoneminder
ShinobiCE
Photoshop CS2
Fortinet
Uploaded
Certifications
General Info
Games
Meal Plans
NC Statutes
2020 Election
Volkswagen
Covid
NCDMV
Toolbox